Once-through steam boiler
                    KDKE Series
                 
                
                    
                         
                     
                    
                        Feature
                        
                            - Dry steam is generated 4~5 minutes after ignition without the loss of preheating load, reducing fuel cost.
- A high performing boiler that achieves high efficiency with exclusive heat transfer fins.
- Easy to handle as operation, water supply and burner combustion control can be automatically controlled and set with one-touch operation.
- Equipped with a high-performance steam separator to supply high-quality dry steam even with sudden load fluctuations.
- Strong resistance to corrosion caused by scale deposition by equipping patented square shaped lower pipe joint header
- Attaching a low-NOx burner ensures fuel cost saving, and NOx of 40 ppm or less is guaranteed for operation under 4% of O₂. (Option)
- The artificial intelligence D-Brain control enables easier operation and management. (Option)
- Cascade unit control system can minimize installation space and enhance response to load fluctuation.
Standard specifications for once-through steam boiler KDKE series
                        
                            
                                
                                  
                                    | Category | Unit | KDKE-100 | KDKE-200 | KDKE-300 | KDKE-400 | KDKE-500 | KDKE-600 | KDKE-800 | KDKE-1000 | KDKE-1500 | KDKE-2000 | KDKE-2500 | KDKE-3000 | 
                                  
                                    | Boiler specifications | Rated evaporation | kg/h | 100 | 200 | 300 | 400 | 500 | 600 | 800 | 1,000 | 1,500 | 2,000 | 2,500 | 3,000 | 
                                  
                                    | Heat output | MW | 0.07 | 0.15 | 0.22 | 0.30 | 0.37 | 0.45 | 0.60 | 0.75 | 1.12 | 1.50 | 1.87 | 2.25 | 
                                  
                                    | kcal/h | 64,370 | 128,740 | 193,110 | 257,480 | 321,850 | 386,220 | 514,960 | 643,700 | 965,550 | 1,287,400 | 1,609,250 | 1,931,100 | 
                                  
                                    | Efficiency | % | 91% | 
                                  
                                    | Heating area | ㎡ | 3.1 | 4.2 | 4.9 | 4.9 | 4.9 | 4.9 | 9.54 | 9.60 | 9.74 | 20 | 22 | 23 | 
                                  
                                    | Control method | - | ON - OFF | HI - LOW - OFF | 
                                  
                                    | Power | V | 220V x 1ø x 60Hz / 220V x 3ø x 60Hz
 | 220V x 3ø x 60Hz / 380V x 3ø x 60Hz | 
                                  
                                    | Fuel consumption | LNG | N㎥/h | 7.1 | 14.1 | 21.2 | 28.3 | 35.4 | 42.4 | 56.6 | 70.7 | 106.1 | 141.5 | 176.8 | 212.2 | 
                                  
                                    | Propane | N㎥/h | 3.2 | 6.3 | 9.5 | 12.6 | 15.8 | 18.9 | 25.3 | 31.6 | 47.4 | 63.2 | 78.9 | 94.7 | 
                                  
                                    | Butane | N㎥/h | 2.4 | 4.8 | 7.2 | 9.6 | 12.0 | 14.4 | 19.2 | 24.0 | 36.0 | 48.0 | 59.9 | 71.9 | 
                                  
                                    | Diesel | kg/h | 6.9 | 13.7 | 20.6 | 27.5 | 34.3 | 41.2 | 54.9 | 68.7 | 103.0 | 137.4 | 171.7 | 206.0 | 
                                  
                                    | Power consumption | Total electric capacity | kW | 0.45 | 0.75 | 1.22 | 2.15 | 2.15 | 2.34 | 6.0 | 6.0 | 9.8 | 14.8 | 14.8 | 18.8 | 
                                  
                                    | Blower motor | 0.15 | 0.25 | 0.37 | 0.55 | 0.55 | 0.74 | 3.7 | 3.7 | 7.5 | 11.0 | 11.0 | 15.0 | 
                                  
                                    | Water pump | 0.2 | 0.4 | 0.75 | 1.5 | 1.5 | 1.5 | 2.2 | 2.2 | 2.2 | 3.7 | 3.7 | 3.7 | 
                                  
                                    | Connection diameter | Steam outlet | A | 25 | 25 | 32 | 40 | 40 | 40 | 50 | 50 | 65 | 80 | 80 | 80 | 
                                  
                                    | Water inlet | 20 | 20 | 20 | 20 | 20 | 20 | 25 | 25 | 25 | 40 | 40 | 40 | 
                                  
                                    | Drainage outlet | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 
                                  
                                    | Oil inlet | 15 | 15 | 15 | 20 | 20 | 20 | 25 | 25 | 25 | 32 | 32 | 32 | 
                                  
                                    | Gas inlet | 25 | 25 | 25 | 40 | 40 | 40 | 40 | 40 | 50 | 50 | 50 | 50 | 
                                  
                                    | Flue | ø mm | 150 | 200 | 200 | 250 | 250 | 300 | 300 | 300 | 350 | 400 | 500 | 500 | 
                                  
                                    | External size | Width(W) | mm | 990 | 800 | 1,120 | 1,130 | 1,000 | 1,260 | 1,440 | 1,500 | 1,650 | 2,450 | 2,460 | 2,510 | 
                                  
                                    | Length(L) | 1,500 | 1,300 | 1,630 | 1,310 | 1,570 | 1,790 | 1,690 | 1,750 | 2,250 | 2,650 | 2,650 | 2,630 | 
                                  
                                    | Height(H) | 1,860 | 1,920 | 2,080 | 2,160 | 2,160 | 2,420 | 2,390 | 2,350 | 2,620 | 3,130 | 3,230 | 3,290 | 
                                  
                                    | Weight | kg | 490 | 520 | 710 | 850 | 880 | 1,400 | 1,500 | 1,620 | 1,670 | 4,100 | 4,300 | 4,900 | 
                                
                            
                         
                        
                            
                                - The rated evaporation amount is based on the water supply temperature of 20℃ and steam pressure of 1MPa. (KDKE-100~200 is 0.7MPa.)
- 
                                    Fuel consumption is based on the low-level calorific value.
 Low-level calorific value ① LNG : 10,000 kcal/N㎥ ② Propane : 22,400 kcal/N㎥ ③ Butane : 10,000 kcal/N㎥ ④ Diesel : 10,000 kcal/N㎥ (Low-level calorific value, specific gravity  0.836)
- These specifications are subject to change without prior notice to improve product performance.
- This specification is based on a gas boiler. For detailed specifications, refer to the specification table.
 
                     
                 
             
            
                
                    Condensing high efficiency once-through steam boiler
                    KDKE-HE Series
                 
                
                    
                         
                        
                     
                    
                        Feature
                        
                            - Equipped with a high-performance water supply pre-heater (STS-304/316), it absorbs the high-temperature exhaust gas’s heat generated after combustion as much as possible, and increases the water inlet temperature to achieve more than 99% efficiency.
- As the conductivity of boiler water is maintained within the allowable value by automatically measuring the concentration of boiler water, there is no carry-over and the lifespan is extended.
- Compact body design reduces the volume of retained water and allows steam to be generated quickly within 3~5 minutes after burner ignition.
- Easy to handle as operation, water supply and burner combustion control can be automatically controlled and set with one-touch operation
- Equipped with a high-performance steam separator to supply high-quality dry steam even with sudden load fluctuations.
- Attaching a low-NOx burner ensures fuel cost saving, and NOx of 40 ppm or less is guaranteed for operation under 4% of O₂. (Option)
- The artificial intelligence D-Brain control enables easier operation and management. (Option)
                            
                            
                                Integrated boiler control system
                                
                                    - Cascade unit control system can minimize installation space and enhance response to load fluctuation.
 
                         
                        Standard specifications for condensing high efficiency once-through type of steam boiler KDKE-HE series
                        
                            
                                
                                  
                                    | Category | Unit | KDKE-400HE | KDKE-500HE | KDKE-800HE | KDKE-1000HE | KDKE-1500HE | KDKE-2000HE | KDKE-2500HE | KDKE-3000HE | KDKE-4000HE | 
                                  
                                    | Boiler specifications | Rated evaporation | kg/h | 400 | 500 | 800 | 1,000 | 1,500 | 2,000 | 2,500 | 3,000 | 4,000 | 
                                  
                                    | Heat output | MW | 0.30 | 0.37 | 0.60 | 0.75 | 1.12 | 1.50 | 1.87 | 2.25 | 2.99 | 
                                  
                                    | kcal/h | 257.480 | 321,850 | 514,960 | 643,700 | 965,550 | 1,287,400 | 1,609,250 | 1,931,100 | 2,574,800 | 
                                  
                                    | Efficiency | % | 99% | 
                                  
                                    | Heating area | ㎡ | 4.9 | 4.99 | 9.5 | 9.7 | 9.99 | 20.00 | 22 | 23 | 29 | 
                                  
                                    | Control method | - | HI - LOW - OFF | 
                                  
                                    | Power | V | 220V x 3ø x 60Hz / 380V x 3ø x 60Hz | 
                                  
                                    | Fuel consumption | LNG | N㎥/h | 26.01 | 32.51 | 52.02 | 65.02 | 97.53 | 130.04 | 162.55 | 195.06 | 260.08 | 
                                  
                                    | Propane | N㎥/h | 11.61 | 14.51 | 23.22 | 29.03 | 43.54 | 58.05 | 72.57 | 87.08 | 116.11 | 
                                  
                                    | Butane | N㎥/h | 8.88 | 11.02 | 17.63 | 22.04 | 33.06 | 44.08 | 55.10 | 66.12 | 88.16 | 
                                  
                                    | Diesel | kg/h | - | - | - | - | - | - | - | - | - | 
                                  
                                    | Power consumption | Total electric capacity | kW | 2.35 | 2.35 | 6.0 | 6.0 | 9.8 | 14.8 | 14.8 | 18.8 | 22.3 | 
                                  
                                    | Blower motor | 0.75 | 0.75 | 3.70 | 3.70 | 7.5 | 11.0 | 11.0 | 15.0 | 18.5 | 
                                  
                                    | Water pump | 1.5 | 1.5 | 2.2 | 2.2 | 2.2 | 3.4 | 3.4 | 3.7 | 3.7 | 
                                  
                                    | Connection diameter | Steam outlet | A | 40 | 40 | 50 | 50 | 65 | 80 | 80 | 80 | 100 | 
                                  
                                    | Water inlet | 25 | 25 | 25 | 25 | 25 | 40 | 40 | 40 | 50 | 
                                  
                                    | Drainage outlet | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 
                                  
                                    | Gas inlet | 40 | 40 | 40 | 40 | 50 | 50 | 50 | 50 | 50 | 
                                  
                                    | Flue | ø mm | 250 | 250 | 300 | 300 | 350 | 400 | 500 | 500 | 500 | 
                                  
                                    | External size | Width(W) | mm | 1,000 | 1,000 | 1,550 | 1,600 | 1,650 | 2,450 | 2,460 | 2,510 | 2,560 | 
                                  
                                    | Length(L) | 1,900 | 1,900 | 2,100 | 2,150 | 2,550 | 3,050 | 3,050 | 2,750 | 2,750 | 
                                  
                                    | Height(H) | 2,160 | 2,160 | 2,450 | 2,650 | 2,700 | 3,130 | 3,230 | 3,290 | 3,730 | 
                                  
                                    | Weight | kg | 1,100 | 1,240 | 1,710 | 2,000 | 2,300 | 4,400 | 5,200 | 6,300 | 7,200 | 
                                
                            
                         
                        
                            
                                - The qualified evaporation amount is based on the water supply temperature of 20℃ and steam pressure of 1MPa.
- 
                                    Fuel consumption is based on the low-level calorific value.
 Low-level calorific value ① LNG : 10,000 kcal/N㎥ ② Propane : 22,400 kcal/N㎥ ③ Butane : 10,000 kcal/N㎥ ④ Diesel : 10,000 kcal/N㎥ (Low-level calorific value, specific gravity 0.836)
- These specifications are subject to change without prior notice to improve product performance.
- This specification is based on a gas boiler. For detailed specifications, refer to the specification table.